Representative residential rooftop solar array used for the Tarlac case study
Representative residential solar installation. This photograph is not the documented Tarlac property.
Tarlac City, Tarlac

What a monitored 2.72 kWp Tarlac rooftop produced

A published monitoring study recorded 3,699 kWh of annual generation from a 2.72 kWp grid-connected rooftop system in Tarlac City.

2.72kWp
3,699kWh/year
1,360kWh/kWp
Review evidence
Representative tropical rooftop solar installation on a low-rise building
Representative institutional-scale rooftop solar setting. This photograph is not the documented Southern Leyte project.
Southern Leyte

First-year output from an 11.76 kWp Southern Leyte project

A DOE-documented orphanage project produced 15,876 kWh in its first year, equivalent to about 1,350 kWh per installed kWp.

11.76kWp
15,876kWh/year
1,350kWh/kWp
Review evidence
Representative rooftop solar installation on closely spaced tropical homes
Representative mixed-use urban rooftop setting. This photograph is not the documented Marikina residence-and-office.
Marikina, Metro Manila

A mixed residence-and-office rooftop in Marikina

A DOE-documented 11 kWp residence-and-office system recorded 15,930.3 kWh of annual output and an 83.5% performance ratio.

11kWp
15,930.3kWh/year
1,448kWh/kWp
Review evidence
Representative commercial rooftop solar array used to illustrate an urban pilot project
Representative commercial rooftop solar installation. This photograph is not either documented Metro Manila pilot roof.
Pasig, Metro Manila

Why two Metro Manila rooftops can produce different yields

A 6.16 kWp Meralco pilot in Pasig produced 6.87 MWh in its first year—lower specific yield than the documented Marikina example, illustrating site and period variability.

6.16kWp
6,870kWh/year
1,115kWh/kWp
Review evidence
Representative aerial view of a small Philippine island community in Palawan
Representative Philippine island setting from Palawan. This photograph is not the documented Gilutongan, Cebu installation.
Gilutongan Island, Cebu

An off-grid Cebu project where usable energy differed from potential

A study of a 7.92 kWp off-grid system serving 11 households estimated 6,510 kWh of potential annual energy but 4,674.5 kWh of usable supplied energy, showing the importance of storage, load matching, and operating constraints.

7.92kWp
4,674.5kWh/year
590kWh/kWp
Review evidence